E. O. SCHWEITZER MANUFACTURING, A DIVISION OF SEL
24
UNDERGROUND FAULT INDICATORS
AR-URD
Underground AutoRANGER
Key Features
System-Wide Adaptability
The Underground AutoRANGER’s autoconfiguration features decrease the
need for crew training, selection analysis, and inventory, resulting in fewer
application errors.
Minimal Maintenance
The AutoRANGER’s ability to adjust for load fluctuations results in a
decreased need for field service. Choose a target-only (no LED) display
option to eliminate the need for a battery. BEACON
LED models have a
15-plus-year product life
minimize trips to the field to replace batteries.
Configuration Choices Optimize Performance
Ensure the best fault-indicating solution for your underground application
by choosing from a wide variety of single- and three-phase display
options, including remote displays that eliminate the need to open the
enclosure to check the fault indicator’s status.
Autoadjusting Trip-Level Selection
Automatic trip-level selection based on sampled load current
makes the AR-URD suitable for applications with fault currents ranging
from as low as 50 A to greater than 1200 A. This feature simplifies ordering
and inventory and reduces maintenance and application errors.
Line-Powered Functionality
Energy required to power the microprocessor comes from monitored
load current rather than a battery, decreasing maintenance and cost of
ownership.
Dynamic Trip-Response Times
By monitoring current, the AR-URD automatically adjusts its trip-response
time to better coordinate with upstream protection.
Current-Activated Timed Reset
Each AR-URD derives a normalization current as a function of measured
circuit load. The AR-URD uses the normalization current to distinguish
circuit restoration from backfeed current; it is this threshold that the
AR-URD must detect before initiating the reset timer (0, 2, 4, or 8 hours).
Choose one low-maintenance fault indicator
for your underground applications.
Underground AutoRANGER application.
Specifications
Fault-Sensing Range 50 to 1200 A
Voltage Range Equal to voltage class of shielded
underground cable
Minimum Operating Current 3 A
Current-Activated Timed Reset 0, 2, 4, or 8 hours
Battery (for BEACON LED
display only)
3.6 V high-capacity 2.4 Ah lithium
battery with a 20-year shelf life
Dynamic Trip-Response Time Function of trip level (see graph above)
Inrush Restraint Response Time 5 cycles
Temperature Range —40° to +85°C
0.01
0.1
1
10
100
100001000 10 100
F a ult Current (Amps)
Response Time (Cycles)
The Underground AutoRANGER’s dynamic trip-response time improves
coordination with upstream protection, maximizing reliable performance.
See page 20 for application with
the RadioRANGER
Wireless Fault
Indication System.