Use the CRSRTT tool (sold separately)
to field-test and manually reset the
Overhead AutoRANGER
™
.
AutoRANGER
™
Fault Indicators providing
fault indication in Kodiak, Alaska.
Install the AutoRANGER
™
with a single
hot stick.
Applications
Overhead
• Provides clear visual indication of the fault path to line crews in
the field.
• Reduces fault-locating time by guiding line crews to the faulted line
section.
• Allows line crews to easily distinguish between temporary and
permanent faults.
• Provides a simple, economical way to improve utility reliability
metrics by reducing outage durations.
Rural
• Automatic trip value selection as low as 50 A.
• TR(TV)
TM
feature (Timed Reset as a function of Trip Value) allows
additional time for line crews to find faults on remote lines.
Troubleshooting
• Distinct eight-hour temporary indication leads line crews to
troubleshoot problematic sections of line.
• Allows line crews to investigate the cause of self-clearing faults and
successful trip and reclose operations to improve circuit reliability.
Self-adjusting fault indicator for system-wide
application
—
one long-life product for all
system loads.
OVERHEAD FAULT INDICATORS
AR-OH
—
Overhead AutoRANGER
™
Key Features
• Reduce engineering time, inventory, and misapplication with self-
adjusting trip levels.
• Automatically adjusts its trip value based on the load current,
eliminating the need to specify a trip value.
• Distinct temporary (amber) and permanent (red) fault indications
provide the flexibility of tracking down self-clearing faults.
• The inrush restraint feature allows for coordinated integration with
automatic reclosing schemes.
• Intelligent LED display provides the appropriate level of intensity for
ambient lighting conditions.
• The best battery-saving technology in the industry provides more
than 2,500 flashing hours of operation.
• Patented Ramp-Down Restraint
®
feature prevents false activation
after extended circuit lockout.
• Rugged construction ensures long product life.
• Quick, simple installation.
• Installswithasinglehotstick
—
no extra clamps or screws
• Zero maintenance
• TestandmanuallyresetwiththeCRSRTTtool
Specifications
Trip Value Range 50 to 1200 A
System Voltage Range (L-L) 4160 V to 69 kV
Maximum Fault Current 25 kA for 10 cycles
Trip Response Time 24 ms
Permanent Flash Clearing Times
50 and 100 A Trip Levels 8 hours
200 to 1200 A Trip Levels 4 hours
Temporary Flash Clearing Time 8 hours
Outer Diameter
Clamping Range
0.30" to 1.50"
Battery 3.6 V high-capacity 8.5 Ah lithium
battery with a 20-year shelf life
Flash Life 2500+ hours (625 four-hour events)
Temperature Range —40° to +85°C
Approximate Weight 575 g (1.27 lbs)