Tel: +1.847.362.8304 | Fax: +1.847.362.8396 | www.eosmfg.com
E. O. SCHWEITZER MANUFACTURING, A DIVISION OF SEL
18
Underground Fault
Indicator Feature
Table
Manual Reset
Fault Indicators
Voltage Reset Faulted Circuit Indicators PILC
Family
Current Reset Faulted Circuit Indicators Timed Reset Fault Indicators
Test Point Voltage Reset Family Secondary Voltage Reset Family Current Reset Family Underground AutoRANGER
Family Timed Reset Family
MR MB
ERL
TPRI TPRV TPRL TPRB TPR3 SRI SRV SRL SRB SR3 CRI CRV CRL CRB CR3 1ARUI 1ARUV 1ARUL 1ARUB 3ARU3 TRI TRV TRL TRB TR3
APPLICATION
Single-Phase
Three-Phase
+ + + + + + + + + + +
Troubleshooting
Three-Phase Reset
3 3 3
RESET TYPE
Manual Reset
CATR CATR CATR CATR CATR
Electrostatic Reset
Test Point Voltage Reset
Secondary Voltage Reset
Current Reset
Timed Reset
CATR CATR CATR CATR CATR
DISPLAY OPTIONS
Integral Target
Remote Target
Integral LED B
Remote LED B B B B B
Remote Target With LED B B B B B B B B B B
Three-Phase Target
Three-Phase Target With LED 4 4
Tamperproof Bolt Display
RadioRANGER
Magnetic Probe
STANDARD FEATURES
Undelayed Trip (1 ms)
Undelayed Trip (8 ms)
Delayed Trip Response Time
Replaceable Lithium AA Cell B B B B
Nonreplaceable Lithium C Cell
Inrush Restraint
Discrete Time-Current Curve
OPTIONAL FEATURES*
Inrush Restraint
Auxiliary Contact
Window Mounting Kit
Delayed Trip (24 ms)
Snap-Action Clamp
Nonreplaceable Lithium C Cell B B
Junction Shield
Constant Calibration
Test Point Phase Sensor
T T T T
TRIP RATINGS
25 to 800 A
50 to 1000 A
50 to 1200 A
60 to 1200 A
T T T T
100 to 800 A
100 to 1200 A
600 to 1200 A
Self-Adjusting (50 A to 1200 A)
POWER SOURCE
Line-Powered
Secondary Source
Battery B B B B B B B
B B B B B B B
ARMING REQUIREMENTS (MAINTAIN READINESS TO TRIP)
No Arming Requirement
5000 V
L- N
110 to 460 Vac
3 A
LC
RESET REQUIREMENTS
Human Intervention
5000 V
L- N
Continuous
110 to 460 Vac
3 A Continuous
LC
Time
CATR CATR CATR CATR CATR
OUTER DIAMETER CLAMPING RANGE (SPECIFY CABLE OUTER DIAMETER WHEN ORDERING)
0.25" to 1.60"
0.25" to 1.40"
0.75" to 1.60"
0.75" to 2.10"
2.2" to 2.8"
Larger Clamp Options C C C C C C C C C C C C C C C C C C C C C C
SYSTEM VOLTAGE RANGE
Up to 35.5 kV
L- L
Matches Shielded URD Cable Rating
8660 V
L- L
to 34.5 kV
L- L
3
Option is available when selecting the 3 suffix (three-phase reset)
4
Reflective red targets with a center BEACON
LED
B
Option is available when selecting the B prefix (BEACON LED) in model selection
T
Test point phase sensor
C
Please consult factory
*
Not all options are available on all models of a product family
UNDERGROUND FAULT INDICATORS