Chicago Electric 91213 Operations Instructions

Browse online or download Operations Instructions for Power generators Chicago Electric 91213. Chicago Electric 91213 Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
GENERATOR SET
5.5 HP - RECOIL START - 2200W/2400W RATED
Model 91213
OPERATING INSTRUCTIONS
Generators
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at http://www.harborfreight.com
Copyright
©
2004 by Harbor Freight Tools
®
. All rights reserved. No
portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
For technical questions and replacement parts, please call 1-800-444-3353
TO PREVENT SERIOUS INJURY OR DEATH,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
Page view 0
1 2 ... 22

Summary of Contents

Page 1 - GENERATOR SET

GENERATOR SET5.5 HP - RECOIL START - 2200W/2400W RATEDModel 91213OPERATING INSTRUCTIONSGenerators3491 Mission Oaks Blvd., Camarillo, CA 93011Visit our

Page 2 - SKU 91213 PAGE 2

SKU 91213 PAGE 108. Keep all electrical equipment clean and dry. Replace any wiring where the insu-lation is cracked, cut, abraded or otherwise degra

Page 3 - UNPACKING

SKU 91213 PAGE 115. Place the Generator as close as possible to the electrical tools and equipmentbeing powered to reduce the length of extension cord

Page 4

SKU 91213 PAGE 12GROUND CONNECTOR(8)#6AWGGROUNDING WIRE(NOT INCLUDED)GROUNDING ROD(NOT INCLUDED)FIGURE BOIL DIPSTICK(65A)FIGURE CFUEL TANK(30)FUEL TAN

Page 5

SKU 91213 PAGE 133. Before the first use, remove the Fuel Tank Cap (33) and fill the Fuel Tank (30) withunleaded gasoline. Then, replace the Fuel Tan

Page 6

SKU 91213 PAGE 14FUEL TANK (32)5. Turn the Engine Power Switch (2) to its “ON” position. (See Figure F.)ENGINEPOWERSWITCH(2)ONOFFFIGURE F6. Hold the

Page 7

SKU 91213 PAGE 15Powering 120 Volt AC Tools And Equipment:1. Prior to powering tools and equipment, make sure the Generator’s rated voltage,and amper

Page 8

SKU 91213 PAGE 167.NOTE: The Generator features a 10 AMP DC Fuse (9) to protect the DC circuit incase of an overload. Should an overload occur the Fu

Page 9

SKU 91213 PAGE 17damaged electrical wiring, and any other condition that may affect its safe opera-tion. If abnormal noise or vibration occurs, have

Page 10 - GENERAL LOCATION

SKU 91213 PAGE 18PARTS LISTNOTE: Some parts are listed and shown for illustration purposes only, and are notavailable individually as replacement part

Page 12 - FIGURE C

SKU 91213 PAGE 2PRODUCT SPECIFICATIONS.Item Description VAC Electrical Requirements 115 Volts @ 19 AMPs Current Output 60 Hz Continuous/Rated Wattage:

Page 13 - To Start The Engine:

SKU 91213 PAGE 20PARTS LIST - CONTINUEDPart #Description Qty. Part #Description Qty.1A Muffler 1 42A Starting Case Assy. 12A Cylinder Head Bolt 4 43A

Page 14

SKU 91213 PAGE 21ASSEMBLY DIAGRAM - CONTINUED78A79A 80A77A76A75A74A1A2A3A4A 5A6A7A8A9A10A11A12A13A14A15A 16A17A18A19A20A21A22A23A24A25A26A27A28A29A30A

Page 15

SKU 91213 PAGE 22WIRING DIAGRAM

Page 16 - NEGATIVE (-) DC TERMINAL (7)

SKU 91213 PAGE 3WORK AREA1. Keep your work area clean and well lit. Cluttered benches and dark areas inviteaccidents.2. Do not operate power tools in

Page 17

SKU 91213 PAGE 46. Avoid body contact with grounded surfaces such as pipes, radiators, ranges,and refrigerators. There is an increased risk of electr

Page 18 - PARTS LIST

SKU 91213 PAGE 517. Do not use the generator if the Power Switch does not turn it on or off. Anygenerator that cannot be controlled with the Power Sw

Page 19 - SKU 91213 PAGE 19

SKU 91213 PAGE 6HEART PACEMAKER PRECAUTIONSPECIFIC PRODUCT WARNINGS AND PRECAUTIONS1. WARNING! People with pacemakers should consult their ph

Page 20 - PARTS LIST - CONTINUED

SKU 91213 PAGE 71. Gasoline fuel and fumes are flammable, and potentially explosive. Use properfuel storage and handling procedures. Always have mult

Page 21 - ASSEMBLY DIAGRAM - CONTINUED

SKU 91213 PAGE 8MECHANICAL PRECAUTIONS1. ALWAYS make sure the Power Switch is in its “OFF” position. Disconnect thespark plug wire, and allow the Eng

Page 22 - WIRING DIAGRAM

SKU 91213 PAGE 9NOISE PRECAUTIONS1. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing.Always wear ANSI approved ear protection w