Chicago Electric 40432 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
Page 7For technical questions, please call 1-800-444-3353.SKU 40432
When using more than one extension 4.
cord to make up the total length, make
sure each cord contains at least the
minimum wire size required. (See Table
A.)
If you are using one extension cord for 5.
more than one tool, add the nameplate
amperes and use the sum to determine
the required minimum cord size. (See
Table A.)
If you are using an extension cord 6.
outdoors, make sure it is marked with the

is acceptable for outdoor use.
Make sure the extension cord is properly 7.
wired and in good electrical condition.
Always replace a damaged extension

electrician before using it.
Protect the extension cords from sharp 8.
objects, excessive heat, and damp or
wet areas.
RECOMMENDED MINIMUM WIRE GAUGE
FOR EXTENSION CORDS* (120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25’ 50’ 75’ 100’ 150’
0 – 2.0 18 18 18 18 16
2.1 – 3.4 18 18 18 16 14
3.5 – 5.0 18 18 16 14 12
5.1 – 7.0 18 16 14 12 12
7.1 – 12.0 18 14 12 10
12.1 – 16.0 14 12 10
16.1 – 20.0 12 10
TABLE A
* Based on limiting the line volt-
age drop to ve volts at 150% of
the rated amperes.
Symbology
Double Insulated
Canadian Standards Association

V~
Volts Alternating Current
A
Amperes
n
0
xxxx/min.

(RPM)
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments